Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Insights Imaging ; 14(1): 57, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37005941

RESUMEN

BACKGROUND: It has previously been shown that CT scans performed for other indications can be used to identify patients with osteoporosis. This has not yet been tested in a British population. We sought to evaluate the use of vertebral CT attenuation measures for predicting osteoporosis in a British cohort, using dual-energy X-ray absorptiometry (DEXA) as a reference standard. METHODS: Patients who underwent abdominal CT in 2018 and concomitantly underwent DEXA within a six-month interval were retrospectively included. CT attenuation values in Hounsfield units (HU) were measured by placement of a region-of-interest at the central portion of the L1 vertebral body and then compared to their corresponding DEXA score. Receiver operating characteristic (ROC) curves were generated to evaluate the performance of a logistic regression model and to determine sensitivity and specificity thresholds. RESULTS: 536 patients (394 females, mean age 65.8) were included, of which 174 had DEXA-defined osteoporosis. L1 attenuation measures were significantly different (p < 0.01) between the three DEXA-defined groups of osteoporosis (118 HU), osteopenia (143 HU) and normal bone density (178 HU). The area under the ROC curve was 0.74 (95% CI 0.69-0.78). A threshold of 169 HU was 90% sensitive, and a threshold of 104 HU was 90% specific for diagnosing osteoporosis. CONCLUSIONS: Routine abdominal CT can be used to opportunistically screen for osteoporosis without additional cost or radiation exposure. The thresholds identified in this study are comparable with previous studies in other populations. We recommend radiologists engage with primary care and rheumatology providers to determine appropriate cut-off values for further investigation.

2.
Br J Radiol ; 96(1144): 20211351, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36802859

RESUMEN

OBJECTIVES: Evaluate clinical outcomes in transarterial embolisation (TAE) for acute gastrointestinal bleeding (GIB) and determine risk factors for 30-day reintervention for rebleeding and mortality. METHODS: TAE cases were retrospectively reviewed between March 2010 and September 2020 at our tertiary centre. Technical success (angiographic haemostasis following embolisation) was measured. Uni- and multivariate logistic regression analysis were performed to identify risk factors for clinical success (absence of 30-day reintervention or mortality) following embolisation for active GIB or empirical embolisation for suspected bleeding. RESULTS: TAE was conducted in 139 patients (92 (66.2%) male; median age:73, range: 20-95 years) for acute upper GIB (n = 88) and lower GIB (n = 51). TAE was technically successful in 85/90 (94.4%) and clinically successful in 99/139 (71.2%); with 12 (8.6%) reintervention cases for rebleeding (median interval 2 days) and 31 (22.3%) cases of mortality (median interval 6 days). Reintervention for rebleeding was associated with haemoglobin drop > 40 g l-1 from baseline based on univariate analysis (p = 0.047). 30-day mortality was associated with pre-intervention platelet count < 150×109 l-1 (p < 0.001, OR 7.35, 95% CI 3.05-17.71) and INR > 1.4 (p < 0.001, OR 4.75, 95% CI 2.03-11.09) on multivariate logistic regression analysis. No associations were found for patient age, gender, antiplatelet/anticoagulation prior to TAE, or when comparing upper and lower GIB with 30-day mortality. CONCLUSION: TAE had excellent technical success for GIB with relatively high (1-in-5) 30-day mortality. INR > 1.4 and platelet count < 150×109 l-1 were individually associated with TAE 30-day mortality, and pre-TAE > 40 g l-1 haemoglobin decline with rebleeding requiring reintervention. ADVANCES IN KNOWLEDGE: Recognition and timely reversal of haematological risk factors may improve TAE periprocedural clinical outcomes.


Asunto(s)
Embolización Terapéutica , Hemorragia Gastrointestinal , Humanos , Masculino , Anciano , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemorragia Gastrointestinal/terapia , Embolización Terapéutica/efectos adversos , Enfermedad Aguda , Factores de Riesgo
3.
Methodist Debakey Cardiovasc J ; 18(1): 59-61, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35935098

RESUMEN

A 74-year-old female with previous permanent pacemaker insertion for complete heart block and no history of connective tissue disease presented to our regional cardiothoracic center with progressive exertional shortness of breath. Nine years later, when the patient was 83 years old, a computed tomography scan of the thoracic aorta revealed an isolated aneurysm of the aortic root measuring 7.6 × 5.1 cm at the sinus of Valsalva.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Seno Aórtico , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/etiología , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Femenino , Humanos , Seno Aórtico/diagnóstico por imagen , Seno Aórtico/cirugía
4.
Cochrane Database Syst Rev ; 6: CD012673, 2019 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-31220333

RESUMEN

BACKGROUND: The presence of oesophageal varices is associated with the risk of upper gastrointestinal bleeding. Endoscopic variceal ligation is used to prevent this occurrence but the ligation procedure may be associated with complications. OBJECTIVES: To assess the beneficial and harmful effects of band ligation versus no intervention for primary prevention of upper gastrointestinal bleeding in adults with cirrhosis and oesophageal varices. SEARCH METHODS: We combined searches in the Cochrane Hepato-Biliary Group Controlled Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS, and Science Citation Index with manual searches. The last search update was 9 February 2019. SELECTION CRITERIA: We included randomised clinical trials comparing band ligation verus no intervention regardless of publication status, blinding, or language in the analyses of benefits and harms, and observational studies in the assessment of harms. Included participants had cirrhosis and oesophageal varices with no previous history of variceal bleeding. DATA COLLECTION AND ANALYSIS: Three review authors extracted data independently. The primary outcome measures were all-cause mortality, upper gastrointestinal bleeding, and serious adverse events. We undertook meta-analyses and presented results using risk ratios (RRs) with 95% confidence intervals (CIs) and I2 values as a marker of heterogeneity. In addition, we calculated the number needed to treat to benefit (NNTTB) for the primary outcomes . We assessed bias control using the Cochrane Hepato-Biliary domains; determined the certainty of the evidence using GRADE; and conducted sensitivity analyses including Trial Sequential Analysis. MAIN RESULTS: Six randomised clinical trials involving 637 participants fulfilled our inclusion criteria. One of the trials included an additional small number of participants (< 10% of the total) with non-cirrhotic portal hypertension/portal vein block. We classified one trial as at low risk of bias for the outcome, mortality and high risk of bias for the remaining outcomes; the five remaining trials were at high risk of bias for all outcomes. We downgraded the evidence to moderate certainty due to the bias risk. We gathered data on all primary outcomes from all trials. Seventy-one of 320 participants allocated to band ligation compared to 129 of 317 participants allocated to no intervention died (RR 0.55, 95% CI 0.43 to 0.70; I2 = 0%; NNTTB = 6 persons). In addition, band ligation was associated with reduced risks of upper gastrointestinal bleeding (RR 0.44, 95% CI 0.28 to 0.72; 6 trials, 637 participants; I2 = 61%; NNTTB = 5 persons), serious adverse events (RR 0.55, 95% CI 0.43 to 0.70; 6 trials, 637 participants; I2 = 44%; NNTTB = 4 persons), and variceal bleeding (RR 0.43, 95% CI 0.27 to 0.69; 6 trials, 637 participants; I² = 56%; NNTTB = 5 persons). The non-serious adverse events reported in association with band ligation included oesophageal ulceration, dysphagia, odynophagia, retrosternal and throat pain, heartburn, and fever, and in the one trial involving participants with either small or large varices, the incidence of non-serious side effects in the banding group was much higher in those with small varices, namely ulcers: small versus large varices 30.5% versus 8.7%; heartburn 39.2% versus 17.4%. No trials reported on health-related quality of life.Two trials did not receive support from pharmaceutical companies; the remaining four trials did not provide information on this issue. AUTHORS' CONCLUSIONS: This review found moderate-certainty evidence that, in patients with cirrhosis, band ligation of oesophageal varices reduces mortality, upper gastrointestinal bleeding, variceal bleeding, and serious adverse events compared to no intervention. It is unlikely that further trials of band ligation versus no intervention would be considered ethical.


Asunto(s)
Várices Esofágicas y Gástricas/complicaciones , Hemorragia Gastrointestinal/prevención & control , Cirrosis Hepática/complicaciones , Adulto , Várices Esofágicas y Gástricas/mortalidad , Várices Esofágicas y Gástricas/terapia , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/mortalidad , Humanos , Hipertensión Portal/complicaciones , Ligadura/efectos adversos , Ligadura/instrumentación , Ligadura/métodos , Ligadura/mortalidad , Persona de Mediana Edad , Números Necesarios a Tratar , Evaluación de Resultado en la Atención de Salud , Prevención Primaria/métodos , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Espera Vigilante
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...